DLVA-8G10G-75-50-SFF-2 Preliminary

Detector Log Video Amplifier (DLVA)

Quantic PMI Model No. DLVA-8G10G75-50-SFF is an 8.0 to 10.0 GHz Detector Log Video Amplifier. This unit has a dynamic range of -70 dBm to +5 dBm, a log linearity of ±1.8 dB, and a log slope of 50±4 mV/dB.  The package size is 2.00" x 1.50" x 0.40" and has SMA female connectors. 

Product Specifications

General Parameters:
Type: DLVA
Status: Preliminary
Frequency Range: 8 to 10 GHz
Frequency Min: 8 GHz
Frequency Max: 10 GHz
TSS: -73 dBm
Size: 2.00" x 1.254" x 0.40"
Log Slope: 50 ± 4 mV/dB
Log Range: -70 to +5 dBm
Log Linearity: ±1.8 dB
Rise Time: 30 ns
Fall Time: 150 ns
Recovery Time: 500 ns for 10.0 µs PW
Finish: Electroless Nickel Plate 0.0005 to 0.0007 THK Per AMS 2404.
Frequency Flatness: ± 1.2 dB
Dynamic Range: -70 dBm to +5 dBm
Environmental Ratings:
Operating Temperature: -54 °C to +95 °C
Non-Operating Temperature: -65 °C to + 125 °C
Temperature Cycle: MIL-STD-202, METHOD 1070 COND. A
Humidity: MIL-STD-202, METHOD 103B COND. B Maintain RH 95±4 % @ 63 °C ( exceptively allowed RF 85% when temperature-down transition time.) The rate of temperature change : Above 8°C/hours Time : Min.10 period (1period = 24 hours),Min. 1time test every 5 period M
Shock: MIL-STD-202, METHOD 2 13, COND J 20G (DURING OPERATION) &125g, 6 ms saw tooth type, 3-AXIS (No operation)
Vibration: MIL-STD-202
Altitude: MIL-STD-202, METHOD 105C, COND B 200Km (8.47e-7 hPa or 6.353e-7 torr/DURING OPERATION)