PMI Model No. PSD-2G6G-CD-1 is High Power, Switch Box Assembly that provides protection to front-end receivers when in the presence of high power signals.  This is accomplished by sensing the input signal level and then switching the input signal into 50 ohms terminations when a set threshold level is exceeded.  This assembly operates from 2.0 to 6.0GHz and can handle input power levels up to 10 Watts CW.  The unit is supplied with an external 0 to 69dB step attenuator that can be used to adjust the signal levels feeding the internal threshold detector and thereby setting the trigger level of when the unit passes the input RF signal to the output of the switch assembly or when the signal is switched into the internal 50 ohms terminations.  The switching speed is 50ns maximum.  This unit operates on 110VDC, 50/60Hz and is supplied in a housing that measures 15.0” x 10.0” x 4.0”.  This unit is ruggedized and designed for harsh environments and is EMI shielded.

Quick Links: (click the links below for additional information)

Product Feature

Test Report


Specifications:

Final Assembly:
   Frequency Response2.0 to 6.0GHz
   Power110VAC Only, 50.60GHz
   Size15.0" x 10.0" x 4.0"
   FinishPainted Gray
   Weight20 lbs typ.
Pin Diode Switch: 
   Power Handling>= 10W
   Frequency Response  2.0 to 6.0GHz
   Switching Speed< 50ns
Threshold Detector: 
   Frequency Repsonse2.0 to 6.0GHz
   Switching Speed< 50ns
   Output TypeTTL (Compatible with Pin Switch)
   Sensitivity< -40dBm
   Max Power (No Damage)10 dBm
Coupler: 
   Power Handling>= 10W
   Frequency Response2.0 to 6.0GHz
   Coupling Factor20 db
50 Ohm LOAD: 
   Power Handling>= 10W
   Frequency Response2.0 to 6.0GHz
Attenuator: 
   Power Handling> 2W
   Frequency Response2.0 to 6.0GHz
   Attenuation0 - 69 By (1) Front Panel Knob or Thumb Wheel

 


Environmental Ratings:

Temperature: -35ºC to +85 ºC Operating
 -40 ºC to +85 ºC Non-Operating
 Humidity: MIL-STD-202F, Method 103B Cond. B
 Shock: MIL-STD-202F, Method 213B Cond. B
 Vibration: MIL-STD-202F, Method 204D Cond. B
 Altitude: MIL-STD-202F, Method 105C Cond. B
 Temperature Cycle: MIL-STD-202F, Method 107D Cond. A