General Parameters: |
Type: | DLVA |
Status: | Active |
Frequency Range: | 0.5 to 2 GHz |
Frequency Min: | 0.5 GHz |
Frequency Max: | 2 GHz |
TSS: | -44 dBm Min |
TSS (Measured): | -44 dBm Min @ -40 ºC to +85 ºC - Measured -46 dBm |
Size: | 2.50" x 1.50" x 0.44" |
Log Linearity: | ±0.5 dB Max @ +25 ºC - Measured +0.17 dB / -0.18 dB, ±0.75 dB Max @ +40 ºC to +85 ºC - Measured +1.30 dB / -0.00 dB @ +40 ºC, Measured +0.00 dB / -1.42 dB @ +85 ºC |
Rise Time: | 30 ns Max (10% to 90%) - Measured 16.37 ns |
Fall Time: | 500 ns Max (@ Pulse width 100 µs Input) (90% to 10%) - Measured 206.8 ns |
Power Supply: | +12 VDC ±1 VDC @ 125 mA Max - Measured +118 mA, -12 VDC ±1 VDC @ 75 mA Max - Measured -48 mA |
Finish: | Nickel Plating |
Frequency Flatness: | ±0.75 dB Max |
VSWR: | 2.5:1 Max @ +23 dBm - Measured 1.14:1 |
Maximum Input Power(CW): | +23 dBm |
Duty Cycle: | 100% |
Propagation Delay: | 60 ns Max - Measured 49 ns |
DC Offset: | +95 mV +55/-100 mV @ +40 ºC to +85 ºC - Measured +58 mV |
Environmental Ratings: |
Operating Temperature: | -40 ºC to +85ºC |
Non-Operating Temperature: | -57 ºC to +85 ºC |
Humidity: | 90% to 98% MIL-STD-202F, Method 106 |
Shock: | 30G, MIL-STD-202F, Method 213B Cond. C |
Vibration: | 10 to 55 Hz (0.06DA), 55 to 2000 Hz (10G) MIL-STD-202F, Method 204 Cond. B |
Altitude: | 20,000 Feet, MIL-STD-202F, method 105 |