ERDLVA-1840-60-50MV Preliminary

Extended Range Detector Log Video Amplifier (ERDLVA)

Quantic PMI Model ERDLVA-1840-60-50MV is a Extended Range Detector Log Video Amplifier (ERDLVA) that operates from 18 to 40 GHz. This ERDLVA features differential as well as single ended video outputs, and a video test output.

Product Specifications

General Parameters:
Type: DLVA
Status: Preliminary
Frequency Range: 18 to 40 GHz
Frequency Min: 18 GHz
Frequency Max: 40 GHz
TSS: -68 dBm Min
TSS (Measured): -68 dBm Min
Size: 2.37" x 2.32" x 0.42"
Log Slope: 50 mV Nom
Log Range: -60 to 0 dBm Min
Log Linearity: ±2 dB Max at any frequency
Rise Time: 20 ns Typ, 35 ns Max 10% to 90% video output
Recovery Time: 300 ns Typ, 500 ns Max to within 1 dB of small signal gain
Finish: Nickel Plate
Frequency Flatness: ±2 dB Typ, ±2.5 dB Max
VSWR: 2.0:1 Max
Weight: 6 ounces Max
Dynamic Range: -60 to 0 dBm Min
Leakage Level: -60 dBm at 0 dBm all outputs terminated in 50 Ohm
Environmental Ratings:
Operating Temperature: -20°C to +85°C
Non-Operating Temperature: -54°C to +85°C
Humidity: To 100% relative humidity +30°C to +55°C with condensation
Shock: 160 G, half sine wave pulse, with 0.7 to 2 mS duration in 3 axis
Vibration: MIL-STD-167-1A
Altitude: 30,000 FT operating, 40,000 FT Non-Operating, MIL-STD-810D, Method 500.2 procedure 1 & 2