General Parameters: |
Status: | Preliminary |
Frequency Range: | 0.03 GHz to 6.0 GHz |
Frequency Min: | 0.03 GHz |
Frequency Max: | 6.0 GHz |
Insertion Loss: | 4.0dB Max |
Attenuation Range: | 60 dB |
Digital Control: | 8 BIT Binary TTL |
Attenuation Flatness: | 10 dB = +/- 1.0 dB 20 dB = +/- 1.5 dB 40 dB = +/- 3.0 dB 60 dB = +/- 5.0 dB |
Return Loss: | -8.5dB Max |
Input Tracking: | ATTENUATION MUST TRACK INPUT VALUES MONOTONICALLY. WHEN CHANGING FROM ONE SETTING TO ANOTHER, THE ATTENUATION MUST REMAIN BETWEEN THE STARTING ATTENUATION AND THE FINAL ATTENUATION. |
Power Supply: | +12VDC@ 155mA MAX (10.BVDC minimum and 13.2VDC maximum) |
Finish: | Painted Blue |
Logic Input: | LOGIC "O" (BIT OFF) = -0.3 to +0.8V LOGIC "1" (BIT ON) = +2.0 to +5.0V |
Connectors: | RF - SMA Female |
Mean Attenuation Range: | 60 dB |
Switching Time: | 50 usec Max |
PWR/CTL Connectors: | 15 PIN Micro-D-Female (MATING CONNECTOR SUPPLIED) |
Accuracy of Attenuation: | 0 dB to 30 dB = +/-1.0 dB 30 dB to 50 dB = +/-1.3 dB 50 dB to 60 dB = +/-1.5 dB |
Environmental Ratings: |
Operating Temperature: | -40°C TO +85°C |
Non-Operating Temperature: | -65°C TO +125°C |
Humidity: | MIL-STD-202F, METHOD 103B COND. B |
Shock: | MIL-STD-202F, METHOD 213B COND. B |
Vibration: | MIL-STD-202F, METHOD 204D COND. B |
Altitude: | MIL-STD-202F, METHOD 105C COND. B |
Temperature Cycle: | MIL-STD-202F, METHOD 107 |
Fungus: | MIL-STD-810C, METHOD 508.2 |