General Parameters: |
Status: | Active |
Frequency Range: | 22.5 to 27.5 GHz |
Frequency Min: | 22.5 GHz |
Frequency Max: | 27.5 GHz |
Insertion Loss: | 2.2 dB Max |
Insertion Loss (Measured): | 2.2 dB Max - Measured 3.29 dB |
Attenuation Range: | 1 to 51.175 dB |
Digital Control: | 11 Bit |
VSWR: | 2.2:1 Max - Measured 1.8:1 |
Operating Input Power: | 10 mW (CW or Peak) |
Attenuation Flatness: | @ 20 dB: ± 1.0 dB Max - Measured ±0.51 dB, @ 50 dB: ± 2.0 dB Max - Measured ±0.58 dB |
Attenuation Accuracy: | ± 1.0 dB Max - Measured: 0 to 10 dB: ± 0.14 dB, 10 to 30 dB: -0.05 dB, 30 to 50 dB: 0.12 dB |
Swiching Time: | 500 ns Max - Measured 450 ns |
Power Supply: | +15 V @100 mA Max - Measured 25 mA |
Connectors: | 2.92mm Female Input and Output |
Size: | 1.8" x 1.15" 0.4" |
Environmental Ratings: |
Operating Temperature: | -40 ºC to +85 ºC |
Non-Operating Temperature: | -54 ºC to +100 ºC |
Humidity: | 95% Max |
Shock: | MIL-STD-202G, Method 213B Cond. B |
Vibration: | MIL-STD-202G, Method 204D Cond. B |
Altitude: | MIL-STD-202G, Method 105C Cond. B |
Temperature Cycle: | MIL-STD-202G, Method 107D Cond. A |